- The condenser is located directly ahead of a cooling system radiator.
- Prop up wheels antiretractable boots.
- Disconnect a negative wire from the battery.
- By forces of the trained professional make a discharge of a refrigerator path of the К/В system.
- Disconnect from the condenser refrigerator lines, - at once to a zakuporta the open ends of nipple sockets in order to avoid internal pollution of the working highway K/V.
- Remove the condenser fan (see the Section Removal, check and installation of the fan of the K/V condenser).
|
- Turn out four fixing bolts, remove a rack of the lock of a cowl and it is accurate, trying not to damage radiator plates, lay it on the lower section of a casing.
|
|
- By means of a special emphasis record a cowl in the lifted situation, then remove the top panel of a forward casing assembled with a regular emphasis of a cowl.
|
- Release an electrical wiring plait from intermediate clamps on the panel of a forward casing.
|
- Having pulled up, release an electrical wiring from the left and right sections of a forward casing.
|
- Lay a leaf of a cardboard between a radiator and the condenser.
|
- Release fixing nuts and, having given up, take the condenser, - the radiator should be removed from basic hairpins, and to delay the condenser a little forward.
|
|
|